Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
2.
Acta ortop. bras ; 29(1): 39-44, Jan.-Feb. 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1152725

ABSTRACT

ABSTRACT Objectives: To describe the clinical and radiographic results of patients with traumatic recurrent anterior shoulder dislocation treated with the Bristow-Latarjet procedure. Methods: Retrospective case series including 44 patients (45 shoulders) who underwent the Bristow-Latarjet procedure. The graft was fixed "standing" in 84% of the shoulders, and "lying" in 16%. Results: The follow-up was 19.25 ± 10.24 months. We obtained 96% of good results, with 2 recurrences presented as subluxation. Graft healing occurred in 62% of cases. The graft was positioned below the glenoid equator in 84% of the cases, and less than 10 mm from its edge in 98%. The external rotation had a limitation of 20.7º ± 15.9º, while the internal rotation was limited in 4.0º ± 9.6º. The limitation of rotation and the position of the graft ("standing" or "lying") did not correlate with graft healing (p>0.05). Bicortical fixation was positively correlated with healing (p <0.001). Conclusion: The Bristow-Latarjet technique is indicated for the treatment of recurrent anterior dislocations and subluxations of the shoulder. It is a safe treatment method, which can be used in people with intense physical activity. Limiting shoulder mobility does not prevent patients from returning to their usual occupations. Level of Evidence IV, Case series.


RESUMO Objetivos: Descrever os resultados clínicos e radiográficos do tratamento da luxação anterior recidivante traumática do ombro pela técnica de Bristow-Latarjet. Métodos: Série de casos retrospectiva, incluindo 44 pacientes (45 ombros) submetidos à técnica de Bristow-Latarjet. O enxerto foi fixado "em pé" em 84% dos ombros, e "deitado" em 16%, utilizando 1 parafuso metálico. Resultados: O seguimento foi de 19,25 ± 10,24 meses. Obtivemos 96% de bons resultados, sendo 2 recidivas sob a forma de subluxação. A consolidação ocorreu em 62% dos casos. O enxerto foi posicionado abaixo do equador da glenoide em 84% das vezes, e a menos de 10 mm da sua borda em 98%. A rotação externa apresentou limitação de 20,7º ± 15,9º, enquanto a rotação interna 4,0º ± 9,6º. A limitação das rotações e a posição do enxerto ("em pé" ou 'deitado") não se correlacionaram com a consolidação do enxerto. A fixação bicortical correlacionou-se positivamente com a consolidação. Conclusões: A técnica de Bristow-Latarjet está indicada para o tratamento da instabilidade anterior recidivante do ombro. É um método de tratamento seguro, que pode ser utilizado em pessoas com atividade física intensa. A limitação da mobilidade do ombro não impede os pacientes de voltarem às suas ocupações habituais. Nível de Evidência IV, Série de casos.

3.
São Paulo med. j ; 133(1): 13-19, Jan-Fev/2015. tab, graf
Article in English | LILACS | ID: lil-733006

ABSTRACT

CONTEXT AND OBJECTIVE: Optimal management of knee osteoarthritis requires a combination of pharmacological and non-pharmacological methods. The use of lateral wedge insoles to treat medial knee osteoarthritis is recommended, but there is still controversy about its efficacy. The purpose of this study was to ascertain whether the use of lateral wedge insoles can diminish pain and improve function in patients with medial knee osteoarthritis. DESIGN AND SETTING: Prospective randomized trial conducted in a tertiary-level hospital. METHODS: We prospectively enrolled 58 patients with medial knee osteoarthritis and randomized them to use either a lateral wedge insole with subtalar strapping (Group W), or a neutral insole with subtalar strapping (Group N - control). All the patients were instructed to use the insole for five to ten hours per day. A visual analogue pain scale, the Western Ontario and McMaster Universities Arthritis Index (WOMAC) and the Lequesne questionnaire were applied at baseline and at weeks 2, 8 and 24. RESULTS: At weeks 8 and 24, both groups showed lower scores for WOMAC (P = 0,023 and P = 0,012 respectively). There were no statistically significant differences between the groups regarding the visual analogue pain scale, WOMAC or Lequesne results at any time evaluated. CONCLUSION: The use of a lateral wedge insole with subtalar strapping improved the patients' symptoms and function but was not superior ...


CONTEXTO E OBJETIVO: O manejo ideal da osteoartrite de joelhos requer combinação entre modalidades farmacológicas e não farmacológicas. O uso de palmilhas valgizantes no tratamento da osteoartrite medial do joelho é recomendado, mas sua eficácia ainda é controversa. Este estudo objetiva verificar se o uso da palmilha valgizante pode diminuir a dor e melhorar a função dos pacientes com osteoartrite medial dos joelhos. DESENHO E LOCAL: Ensaio clínico prospectivo e randomizado conduzido em hospital de atenção terciária. MÉTODOS: Alocamos prospectivamente 58 pacientes com osteoartrite medial dos joelhos que foram randomizados para fazer uso de palmilha valgizante com amarrilho subtalar (Grupo W) ou palmilha neutra com amarrilho subtalar (Grupo N - controle). Todos os pacientes foram orientados a utilizar a palmilha entre cinco e dez horas por dia. Foram aplicados os questionários Western Ontario and McMaster Universities Arthritis Index (WOMAC) e Lequesne, além da escala visual analógica da dor, nos momentos pré e após 2, 8 e 24 semanas. RESULTADOS: Após 8 e 24 semanas, ambos os grupos apresentaram redução dos valores de WOMAC (P = 0,023 e P = 0,012 respectivamente). Não houve diferença estatisticamente significativa entre os grupos nos resultados de WOMAC, Lequesne e escala visual analógica de dor, em nenhum dos momentos avaliados. ...


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Foot Orthoses , Osteoarthritis, Knee/therapy , Pain Measurement/methods , Bandages , Follow-Up Studies , Prospective Studies , Severity of Illness Index , Single-Blind Method , Surveys and Questionnaires , Treatment Outcome
4.
São Paulo med. j ; 133(1): 4-12, Jan-Fev/2015. tab, graf
Article in English | LILACS | ID: lil-733011

ABSTRACT

CONTEXT AND OBJECTIVE: The development of a slow and progressive mechanical model for osteoarthritis is important for correlation with clinical practice, and for evaluating the effects of disease-modifying medications. A mechanical osteoarthritis model was developed to evaluate the effects of intra-articular hyaluronic acid (HA) injection and oral diacerein administration. DESIGN AND SETTING: Experimental study at the Department of Orthopedics and Traumatology, Universidade de São Paulo. METHOD: Total medial meniscectomy was performed on seven groups of ten Wistar rats each, comprising four control groups (C) and three study groups (S). C.I: operated, non-medicated; C.II: operated, injections of HA vehicle; C.III: non-operated, non-medicated; C.IV: operated, non-medicated, sacrificed three months post-meniscectomy; S.I: operated, receiving intra-articular HA injections; S.II: operated, oral diacerein from the third to the seventh postoperative month; S.III: operated, received both medications. All the animals (except C.IV) were sacrificed seven months post-meniscectomy. All femurs and tibias were assessed histologically. RESULTS: The most severe degenerative histological changes were in the tibias of the operated knees. On the contralateral side, all groups had mild changes on the tibial surface. The femoral surface had ...


CONTEXTO E OBJETIVO: Desenvolver um modelo osteoartrítico mecânico lento e progressivo é importante para correlação com a prática clínica e para avaliar os efeitos de medicamentos modificadores da doença. Um modelo mecânico de osteartrite foi desenvolvido para avaliar os efeitos de injeção intra-articular de hialuronato de sódio (AH) e de administração de diacereína oral. DESENHO E LOCAL: Estudo experimental no Departamento de Ortopedia e Traumatologia, Universidade de São Paulo. MÉTODO: Meniscectomia medial total foi feita em sete grupos de dez ratos Wistar, sendo quatro grupos controle (C) e três grupos estudo (E). C.I: operado, não medicado; C.II: operado, recebendo injeções do veículo do AH; C.III: não operado, não medicado; C.IV: operado, não medicado, sacrificado três meses pósmeniscectomia; EI: operado, recebendo injeções de AH intra-articular; E.II: operado, recebendo diacereína oral do terceiro ao sétimo mês pós-operatório; E.III: operado, recebeu ambas medicações. Todos os animais (exceto C.IV) foram sacrificados sete meses pós-meniscectomia. Todos os fêmures e tíbias foram analisados histologicamente. RESULTADOS: As alterações histológicas degenerativas ...


Subject(s)
Animals , Male , Anthraquinones/administration & dosage , Anti-Inflammatory Agents/administration & dosage , Arthritis, Experimental/drug therapy , Hyaluronic Acid/administration & dosage , Menisci, Tibial/surgery , Osteoarthritis, Knee/drug therapy , Viscosupplements/administration & dosage , Administration, Oral , Arthritis, Experimental/etiology , Arthritis, Experimental/pathology , Disease Models, Animal , Disease Progression , Drug Therapy, Combination , Injections, Intra-Articular , Osteoarthritis, Knee/etiology , Osteoarthritis, Knee/pathology , Random Allocation , Rats, Wistar , Severity of Illness Index
5.
Clinics ; 68(7): 928-933, jul. 2013. tab, graf
Article in English | LILACS | ID: lil-680700

ABSTRACT

OBJECTIVE: To evaluate the functional and radiographic results in patients undergoing shoulder anterior soft tissue stretching in association with open reduction and internal rotation osteotomy to centralize the humeral head as a treatment for Erb-Duchenne obstetric palsy sequelae. METHOD: A total of 35 patients underwent this surgical treatment, and the mean follow-up was 4.6 years. The Mallet scale was applied before and after the surgical procedure. A total of 20 patients underwent computed tomography to assess the glenoid version and humeral head subluxation. RESULTS: Functional improvement was achieved, as evidenced by an increase in the Mallet scale score from 12.14 to 16.46 (p<0.001). The correction of retroversion was achieved once the glenoid version ranged from -21.4 to -12 degrees (p<0.001). The humeral head subluxation improved from 6.5 to 35.2% (p<0.001). Patients older than 6 years of age did not achieve glenohumeral joint improvement with respect to dysplastic abnormalities. CONCLUSION: Internal rotation osteotomy in association with the stretching of anterior soft tissues of the shoulder in patients under the age of 7 years provided improvements in the function, retroversion, and subluxation of the glenohumeral joint. .


Subject(s)
Child , Child, Preschool , Female , Humans , Infant , Male , Brachial Plexus Neuropathies/surgery , Humeral Head/surgery , Osteotomy/methods , Age Factors , Brachial Plexus Neuropathies , Follow-Up Studies , Humeral Head , Postoperative Period , Preoperative Period , Recovery of Function , Rotation , Shoulder Joint , Shoulder Joint/surgery , Tomography, X-Ray Computed , Treatment Outcome
6.
Acta ortop. bras ; 21(1): 12-17, jan.-fev. 2013. tab
Article in Portuguese | LILACS | ID: lil-670850

ABSTRACT

Objetivo: Avaliar se a viscossuplementação com ácido hialurônico em pacientes com artropatia hemofílica grave associada com triancinolona após a lavagem articular com soro fisiológico melhora a dor, a rigidez, a função e a qualidade de vida. Métodos: Onze pacientes com artrite hemofílica de joelhos com e sem acometimento de outras articulações (tornozelos e cotovelos) foram submetidos a lavagem articular com soro fisiológico e subsequente infiltração de hilano e triancinolona em todas as articulações acometidas. Responderam os questionários algo-funcionais (WOMAC e Lequesne), escala analógica visual para dor (VAS) e SF-36, no pré-operatório, e com um e três meses de pós-operatório. Resultados: A dor (VAS e WOMAC dor) e a rigidez (WOMAC rigidez) não apresentaram melhora significativa (p=0,3; p=0,2; p=0,1, respectivamente). Porém a função apresentou uma melhora significativa dada pelo WOMAC função e total (11 pontos em média, p=0,04 e p=0,001, respectivamente). A pontuação no questionário de Lequesne não variou significativamente (p=0,1). Porém tantos os componentes mental como físico do SF 36 tiveram melhoras clinicamente relevantes e significativas (p=0,002). Conclusão: A lavagem articular com soro fisiológico seguida pela infiltração de corticosteroide e hilano é efetiva no tratamento da artropatia hemofílica, sobretudo na melhora funcional e na qualidade de vida. Nível de Evidência IV, Série de casos.


Objective: To assess whether viscosupplementation with hyaluronic acid in patients with severe hemophilic arthropathy associated with triamcinolone after washing with saline improves joint pain, stiffness, function and quality of life. Methods: Eleven patients with hemophilic arthritis of the knee with and without involvement of other joints (elbows and ankles) underwent joint lavage with saline and subsequent injection of Hylan and triamcinolone in all affected joints. The patients answered the algo-functional (Lequesne and WOMAC), visual analog scale for pain (VAS) and SF-36 (quality of life) questionnaires preoperatively, and at one and three months postoperatively. Results: Pain (VAS and WOMAC pain) and stiffness (WOMAC stiffness) did not show significant improvement (p = 0.3, p = 0.2, p = 0.1, respectively). However function had significant improvement given by WOMAC total and function (averaging 11 points, p = 0.04 and p = 0.001). There was no significant variation in scores in Lequesne’s questionnaire (p = 0.1), yet both mental and physical components of SF-36 presented clinically relevant and significant improvements (p = 0.002). Conclusion: Joint lavage with saline followed by injection of corticosteroids and Hylan is effective in the treatment of hemophilic arthropathy, especially in functional improvement and quality of life. Level ofEvidence IV, Case series.


Subject(s)
Humans , Male , Adolescent , Young Adult , Hyaluronic Acid/administration & dosage , Hyaluronic Acid/therapeutic use , Joint Diseases/therapy , Hemophilia A , Osteoarthritis, Knee/therapy , Therapeutic Irrigation , Vascular Stiffness , Viscosupplementation , Pain Measurement , Quality of Life , Surveys and Questionnaires , Data Interpretation, Statistical
7.
Rev. bras. ortop ; 47(6): 741-747, 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-666219

ABSTRACT

OBJETIVO: Avaliar os resultados funcionais e o índice de rerrotura do reparo do manguito rotador por via artroscópica associado ao uso do PRP. MÉTODOS: Série de casos prospectiva, avaliando os resultados do reparo artroscópico do manguito rotador em fileira simples associada ao uso do PRP. Foram incluídas apenas roturas isoladas do supraespinal, com retração inferior a 3cm. O PRP utilizado foi obtido pelo método de aférese, e aplicado em sua forma ativada, com a adição de trombina autóloga, na consistência líquida. A avaliação pós-operatória foi realizada de maneira padronizada, aos 12 meses de seguimento. Foram utilizadas as escalas de Constant-Murley, UCLA e EVA, além da análise da incidência de rerroturas através da ressonância magnética. RESULTADOS: Foram avaliados 14 pacientes (14 ombros). A escala de Constant-Murley evoluiu em média de 45,64 ± 12,29 no pré-operatório para 80,78 ± 13,22 no pós-operatório (p < 0,001). A escala de UCLA sofreu um incremento de 13,78 ± 5,66 para 31, 43 ± 3,9 (p < 0,001). A dor dos pacientes apresentou uma melhora significativa de acordo com a EVA (p = 0,0013), decrescendo de uma mediana de 7,5 (p25% = 6, p75% = 8) para 0,5 (p25% = 0, p75% = 3). Nenhum dos pacientes apresentou rerrotura completa. Em três pacientes (21,4%) foi observada uma rerrotura parcial, sem transfixação. Apenas um paciente evoluiu com complicação (capsulite adesiva). CONCLUSÃO: Os pacientes submetidos ao reparo do manguito rotador por via artroscópica associado ao uso do PRP apresentaram uma melhora funcional significativa e nenhuma rerrotura completa.


OBJECTIVE: To evaluate shoulder functional results and the re tear rate of arthroscopic repair of the rotator cuff augmented with platelet-rich plasma (PRP). METHODS: Prospective case series with single-row arthroscopic repair of the rotator cuff augmented with PRP. Only cases of isolated supraspinatus tears with retraction of less than 3 cm were included in this series. The PRP used was obtained by apheresis. It was applied on liquid consistency in its activated form, with the addition of autologous thrombin. Patients were evaluated after 12 months of the surgical procedure. The Constant-Murley, UCLA and VAS scales were used, and the retear rate was assessed using magnetic resonance imaging (MRI). RESULTS: Fourteen patients were evaluated (14 shoulders). The mean Constant-Murley score was 45.64 ± 12.29 before the operation and evolved to 80.78 ± 13.22 after the operation (p < 0.001). The UCLA score increased from 13.78 ± 5.66 to 31.43 ± 3.9 (p < 0.001). The patients' pain level decreased from a median of 7.5 (p25% = 6, p75% = 8) to 0.5 (p25% = 0, p75% = 3) (p = 0.0013) according to the VAS score. None of the patients presented complete retear. Three patients (21.4%) showed partial retear, without transfixation. Only one patient developed complica tions (adhesive capsulitis). CONCLUSION: Patients submitted to arthroscopic rotator cuff repair augmented with PRP showed significant functional improvement and none of them had com plete retearing.


Subject(s)
Humans , Male , Female , Middle Aged , Arthroscopy , Platelet-Rich Plasma , Rotator Cuff
8.
Acta ortop. bras ; 19(2): 102-105, mar.-abr. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-591176

ABSTRACT

OBJETIVO: Avaliar se a injeção intra-articular de Plasma rico em plaquetas (PRP) pode reduzir a apoptose pós-traumática de condrócitos. MÉTODOS: Foi desenvolvido um estudo experimental duplo-cego com quatro joelhos de coelhos adultos. Após a anestesia, os animais foram submetidos à contusão padronizada dos joelhos. Depois foi injetado 1ml de PRP humano nos dois joelhos esquerdos e 1ml de solução fisiológica (SF) nos dois joelhos direitos. Os dois coelhos foram mantidos no mesmo ambiente sob controle de temperatura, de atividades diárias e de alimentação. A eutanásia dos animais ocorreu dez dias após a intervenção e foram realizadas biópsias da cartilagem de cada joelho. As peças foram preparadas para análise em microscopia eletrônica (ME). RESULTADOS: Quatro preparados para ME foram obtidos, cada um correspondendo a um joelho. Os joelhos-PRP apresentaram as taxas de apoptose de 47,62 por cento (50/105) e de 48,36 por cento (59/122), respectivamente. Nos joelhos-SF as taxas de apoptose foram, respectivamente, 56,67 por cento (17/30) e 70,40 por cento (88/125). A diferença do índice de apoptose nos joelhos-PRP (48,02 por cento) e nos joelhos-SF (67,74 por cento) foi significante (p<0,001) e OR=0,439 (IC95 por cento=0.287-0.673). CONCLUSÃO: A injeção intra-articular de PRP imediatamente ao trauma, reduz as taxas de apoptose (pós-traumática) de condrócitos de coelhos.


OBJECTIVE: To evaluate if the injection of intra-articular platelet-rich plasma (PRP) can reduce impact-induced chondrocyte apoptosis. METHODS: A double-blind experimental study was developed in four knees of two adult rabbits. Each knee was injured after anesthesia. Subsequently, 1ml PRP was injected in the right knees and 1ml of normal saline (NS) in the left knees. The animals were euthanized ten days after the intervention. All cartilage was removed from the 4 knees and prepared for analysis in electron microscopy (EM). RESULTS: Four EM samples were obtained. The PRP-injected knees showed apoptosis rates of 47,62 percent (50/105) and 48,36 percent (59/122), respectively. NS-injected knees showed 56.67 percent (17/30) and 70.40 percent (88/125) of apoptosis. PRP-injected knees had statistically significant less apoptosis (48.02 percent) than NS-injected ones, (67.74 percent, p<0,001) and odds ratio of 0.439 (95 percent CI=0.287-0.673). CONCLUSION: Immediately post-traumatic intra-articular injection of PRP reduces impact-induced chondrocyte apoptosis in rabbits.


Subject(s)
Animals , Rabbits , Apoptosis , Cartilage, Articular , Knee Injuries , Platelet-Rich Plasma , Chi-Square Distribution
9.
Rev. bras. ortop ; 45(1): 12-16, 2010. ilus
Article in Portuguese | LILACS | ID: lil-550559

ABSTRACT

As fraturas da diáfise do úmero (FDU) representam 3 por cento das fraturas do aparelho locomotor; o terço médio da diáfise direita é o mais acometido. Seu tratamento é, na sua maioria, realizado por meio de métodos não cirúrgicos, mas as indicações cirúrgicas nas FDU são adotadas em situações cada vez mais frequentes. A diversidade de opiniões torna difícil o consenso sobre qual o tipo de osteossíntese, qual a técnica cirúrgica, a quantidade e a qualidade dos materiais de síntese a serem utilizados. Temos a impressão de que o melhor método para o tratamento cirúrgico das FDU está longe de ter um consenso entre os especialistas. Acreditamos que os métodos menos invasivos e que privilegiam a estabilidade relativa são os mais adequados, pois complicações mais temidas são menos frequentes.


Humeral shaft fractures (HSF) represent 3 percent of fractures of the locomotor apparatus, the mid-third section of the shaft being the most commonly affected. In the majority of cases, it is treated by non-surgical methods, but surgical indications in HSF are increasingly being adopted. The diversity of opinions makes it difficult to reach a consensus regarding to the type of osteosynthesis, surgical technique, and quantity and quality of the synthesis materials to be used. It would appear that specialists are far from reaching a consensus as to the best method for the surgical treatment of HSF. We believe that less invasive methods, which favor relative stability, are the most appropriate methods, as the most feared complications are less frequent.


Subject(s)
Humans , Fracture Fixation, Internal , Humeral Fractures/classification , Humeral Fractures/diagnosis , Humeral Fractures/therapy , Orthopedic Procedures , Orthopedics
10.
Clinics ; 64(10): 975-981, 2009. ilus
Article in English | LILACS | ID: lil-529540

ABSTRACT

OBJECTIVES: The objectives of this study were to develop a pointing device controlled by head movement that had the same functions as a conventional mouse and to evaluate the performance of the proposed device when operated by quadriplegic users. METHODS: Ten individuals with cervical spinal cord injury participated in functional evaluations of the developed pointing device. The device consisted of a video camera, computer software, and a target attached to the front part of a cap, which was placed on the user's head. The software captured images of the target coming from the video camera and processed them with the aim of determining the displacement from the center of the target and correlating this with the movement of the computer cursor. Evaluation of the interaction between each user and the proposed device was carried out using 24 multidirectional tests with two degrees of difficulty. RESULTS: According to the parameters of mean throughput and movement time, no statistically significant differences were observed between the repetitions of the tests for either of the studied levels of difficulty. CONCLUSIONS: The developed pointing device adequately emulates the movement functions of the computer cursor. It is easy to use and can be learned quickly when operated by quadriplegic individuals.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Computer Peripherals , Communication Aids for Disabled/standards , Head Movements/physiology , Quadriplegia/physiopathology , User-Computer Interface , Analysis of Variance , Software
11.
Clinics ; 63(5): 601-606, 2008.
Article in English | LILACS | ID: lil-495033

ABSTRACT

OBJECTIVE: To compare skin folds in the dominant and nondominant halves of the body in a group (A) of 20 individuals with cerebral palsy and spastic hemiplegia and a group (B) of 30 normal volunteers. METHOD: Body mass, height and skin folds were measured, and the percentage of body fat was estimated by adipose tissue measurement and densitometry. The mean age in group (A) was 24.6 ± 5.6 years (ranging from 16.1 to 38.1 years). The mean age in group (B) was 25.3 ± 3.8 years (ranging from 19.0 to 34.11 years). RESULTS: Statistically significant differences were observed between the dominant and nondominant halves of the body for biceps, triceps, thoracic, suprailiac, thigh and midcalf skin folds in group A; the biceps, subscapular, midaxillary, suprailiac, abdominal, thigh and midcalf skin folds in group B; and the percentage fat obtained by adipose tissue measurement in both groups. Statistically significant differences were observed for the triceps skin fold when the dominant halves of the body in groups A and B were compared. Statistically significant differences were also observed for the biceps, triceps, thigh and midcalf skin folds as well as the adipose tissue measurements between the dominant and nondominant halves of the body in the two groups. The percentage fat as estimated by densitometry was significantly correlated with the adipose tissue measurement. CONCLUSION: There were statistically significant differences between the skin folds in the dominant and nondominant halves of the body, both in group A and in group B (greater in group A). There was a statistically significant correlation in the percentage fat as estimated by densitometry and as measured by adipose tissue in groups A and B.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Young Adult , Anthropometry/methods , Body Composition/physiology , Cerebral Palsy/pathology , Functional Laterality , Hemiplegia/pathology , Skinfold Thickness , Absorptiometry, Photon , Analysis of Variance , Adipose Tissue/pathology , Case-Control Studies , Statistics, Nonparametric , Whole Body Imaging , Young Adult
12.
Acta ortop. bras ; 15(1): 6-8, 2007. tab
Article in Portuguese | LILACS | ID: lil-450329

ABSTRACT

Métodos de armazenamento de aloenxertos podem alterar certas características mecânicas dos tecidos. Com o objetivo de analisar a influência do fenômeno de congelamento e do tempo de armazenamento sobre as propriedades biomecânicas de tendões, os autores estudaram 40 tendões calcâneos obtidos de 20 cadáveres humanos com idade média de 41,95 anos, variando de 31 a 54 anos, sendo 17 do sexo masculino e três do sexo feminino. De cada cadáver foram retirados dois tendões, sendo que um foi testado a fresco e o contralateral congelado a - 85° C em freezer elétrico, durante um período de seis ou 12 semanas. Os corpos de prova foram submetidos a ensaios de tração em uma máquina de ensaios mecânicos Kratos K5002, fornecendo gráficos força-deformação. Foram analisados os parâmetros de força no limite de resistência máxima, rigidez, tensão no limite de resistência máxima, deformação relativa e módulo de elasticidade. Os resultados foram comparados e a analisados estatisticamente pelo método de "t-student", com índice de significância de 0,05, sendo que não houve diferença significativa nos valores obtidos entre os grupos. Concluímos que o congelamento a - 85° C não altera as propriedades biomecânicas de tendões, a despeito do tempo de armazenamento.


Allograft storage methods can change some mechanical characteristics of tissues. With the objective of analyzing the influence of freezing phenomenon and storage time on tendonsÆ biomechanical properties, the authors studied 40 calcaneus tendons obtained from 20 human cadavers, with an average age of 41.95 years, ranging from 31 to 54 years old, being 17 males and three females. From each cadaver, two tendons were removed, one tested in its fresh state and the contralateral one frozen at -85° C in an electric freezer, during a period of six or 12 weeks. The bodies of evidence were submitted to traction assays in a Kratos K5002 mechanical assay machine, delivering strength-deformation graphics. Strength at maximum resistance limit, stiffness, tension at maximum resistance limit, relative deformation, and elasticity module parameters were assessed. The results were compared and statistically analyzed by "StudentÆs t- method", with a significance level of 0.05, with no significant difference on values achieved between groups. We concluded that freezing at -85° C does not cause changes to tendonsÆ biomechanical properties, despite of storage time.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Freezing , Transplantation, Homologous , Achilles Tendon/anatomy & histology , Biomechanical Phenomena , Cadaver
13.
Clinics ; 62(6): 741-748, 2007. ilus, graf, tab
Article in English | LILACS | ID: lil-471794

ABSTRACT

OBJECTIVE: In bone injury, repair results in local increased vascularity and bone marrow remodeling. Characterizing the vascular and metabolic imaging patterns of the proximal femur following an intertrochanteric osteotomy may help clinicians decide proper management of the patient. Our objective was to measure Doppler sonography and scintigraphy interval changes in the proximal femur following intertrochanteric osteotomy and compare imaging and histomorphometric measurements in the late post-operative stage (6 weeks after surgery) in a rabbit model of bone injury. MATERIALS AND METHODS: Both hips of 12 adult rabbits were imaged with power Doppler sonography and scintigraphy prior to and after (7 days and 6 weeks) unilateral osteotomy. Accuracy of the imaging methods was evaluated using hip operative status and histomorphometric results (vascular fractional area and number of vessels per area unit) as reference standard measures. RESULTS: A significant difference in the mean number of pixels was noted between operated and non-operated femura in late post-operative power Doppler examinations (P=0.049). Although without reaching statistical significance, the AUC of Doppler measurements (AUC=0.99) was numerically greater than the AUC of scintigraphy measurements (AUC=0.857±0.099) (P=0.15) in differentiating proximal femura with regard to their fractional vascular areas in the late post-operative stage. In contrast, scintigraphy tended to perform better (AUC=0.984±0.022) than Doppler ultrasound (AUC=0.746±0.131) to demonstrate the vascularity intensity per area unit (P=0.07) in the late stage. CONCLUSION: Our results warrant further investigation to determine the value of different imaging modalities for assessment of pathologic changes following hip surgery. Power Doppler sonography demonstrated larger AUCs (representing higher accuracy) for the discrimination of vascular fractional areas and scintigraphy, for discrimination...


OBJETIVO: Regeneração em casos de lesão óssea resulta em aumento da vascularização local e remodelamento da medula óssea adjacente. A caracterização imagenológica de padrões vasculares e metabólicos no fêmur proximal após uma osteotomia intertrocantérica pode auxiliar ortopedistas a decidirem qual a terapêutica mais apropriada. O objetivo deste estudo foi avaliar as alterações temporais observadas por ultra-sonografia Doppler e cintilografia no fêmur proximal após a realização de uma osteotomia intertrocantérica; e comparar achados imagenológicos e histomorfométricos no estágio pós-operatório tardio (6 semanas após a cirurgia) num modelo animal de lesão óssea. MATERIAIS AND MÉTODOS: Ambos os quadris de 12 coelhos adultos foram examinados por ultra-sonografia power Doppler e cintilografia antes e após (7 dias e 6 semanas) uma osteotomia unilateral. A acurácia dos métodos de imagem foi avaliada usando-se o status operatório dos quadris and os resultados histomorfométricos (área vascular fracional e número de vasos/unidade de área) como medidas de referência. RESULTADOS: Uma diferença significativa foi observada entre o número médio de pixels presentes no fêmur proximal operado e não-operado ao exame de power Doppler obtido no estágio pós-operatório tardio (P=0.049). Embora ser atingir significância estatística, a área abaixo da curva ("area-under-the-curve") dos exames de power Doppler (AUC=0.99) for numericamente superior à área abaixo da curva dos exames de cintilografia (AUC= 0.857±0.099) (P=0.15) para diferenciar fêmures proximais com relação a suas áreas vasculares fracionais no estágio pós-operatório tardio. Ao contrário, a cintilografia tendeu a apresentar uma "performance" diagnóstica superior (AUC=0.984±0.022) em relação ao Doppler (AUC=0.746±0.131) para demonstrar a quantidade de vasos por unidade de área (P=0.07) no estágio tardio. CONCLUSÃO: Nossos resultados despertam a importância de continuar-se investigando...


Subject(s)
Animals , Rabbits , Bone Diseases , Bone Diseases , Femur , Hip Joint , Osteotomy/methods , Bone Remodeling/physiology , Disease Models, Animal , Epiphyses, Slipped , Epiphyses, Slipped , Femur , Femur , Hip Joint , Hip Joint , Legg-Calve-Perthes Disease , Legg-Calve-Perthes Disease , Postoperative Period , Ultrasonography, Doppler/methods
14.
Clinics ; 60(5): 381-388, Oct. 2005. ilus, tab, graf
Article in English | LILACS | ID: lil-414787

ABSTRACT

OBJETIVO E MÉTODOS: Em virtude do desconhecimento relativo às forças que atuam em uma articulação durante o processo de reabilitação da mão, foi confeccionada uma órtese dinâmica que, acoplada a um dinamômetro, mediu, através de cálculos trigonométricos, a força (entre 0 a 600gf), flexora na articulação interfalângica proximal do terceiro dedo, a 30º, 45º, 60º e 90º de flexão. Estas medidas foram obtidas, em uma população de 40 adultos voluntários, 20 do sexo feminino e 20 do masculino, e confrontadas com idade, sexo e medidas antropométricas como estatura, envergadura e comprimento do dedo. RESULTADOS: Os resultados do estudo demonstraram que o tendão flexor é submetido à máxima força no início da flexão e que a força no tendão flexor diminui conforme aumenta o grau de amplitude articular. Observou uma relação entre o comprimento do dedo e a magnitude da força exercida no tendão durante a flexão do dedo, sendo que nos dedos mais compridos os tendões são submetidos a forças maiores. Quando comparou a estatura e envergadura com a magnitude da força aplicada no tendão flexor, observou uma relação positiva em todos os graus de flexão estudados, exceto a 30º. O sexo masculino apresentou maior força em todos os graus de amplitude articular. CONCLUSÕES: Conclui que é possível medir a força de flexão transmitida pelos tendões flexores através de uma órtese acoplada a um dinamômetro, que esta força é maior nos indivíduos do sexo masculino, com dedos mais longos, de maior altura e envergadura e que tais dados permitirão o desenvolvimento de futuros trabalhos no campo da reabilitação da mão, auxiliando pacientes portadores de lesões de tendões, retração cicatricial, deformidades e rigidez articular.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Finger Joint/physiology , Fingers/physiology , Psychomotor Performance/physiology , Hand Strength/physiology , Tendons/physiology , Biomechanical Phenomena , Fingers/anatomy & histology , Movement
15.
Acta ortop. bras ; 13(3): 115-119, 2005. ilus, graf
Article in Portuguese | LILACS | ID: lil-410757

ABSTRACT

O equilíbrio é o processo de manutenção do centro de pressão (CP), projeção do centro de gravidade no solo, dentro da área da base de suporte do corpo. Este estudo avalia o controle postural em pacientes portadores de lesão unilateral do ligamento cruzado anterior do joelho e de indivíduos saudáveis, através de parâmetros do centro de pressão. Dezenove indivíduos saudáveis entre 18 e 30 anos e dezenove pacientes portadores de lesão unilateral do ligamento cruzado anterior do joelho entre 15 e 33 anos foram avaliados empregando sensores FSCAN MAT® (Tekscan®, Boston, MA, USA). Todos os indivíduos realizaram quatro testes estáticos diferentes com apoio unilateral, variando os lados e a abertura e o fechamento dos olhos. Os parâmetros comprimento total da trajetória, amplitude antero-posterior, amplitude médio-lateral e velocidade máxima do centro de pressão foram calculados. Os resultados mostraram que a dominância dos membros inferiores não exerce influência significativa no equilíbrio dos indivíduos saudáveis, que a visão é um fator importante na estabilização do controle postural e que a lesão unilateral do ligamento cruzado anterior do joelho compromete o equilíbrio em apoio unilateral e em ambos os lados, porém, de modo mais evidente, no lado lesado.


Subject(s)
Humans , Adolescent , Adult , Anterior Cruciate Ligament , Anterior Cruciate Ligament/injuries , Postural Balance , Posture , Knee
16.
Acta ortop. bras ; 11(1): 25-31, jan.-mar. 2003. ilus, tab, graf
Article in Portuguese, English | LILACS | ID: lil-331132

ABSTRACT

The suture anchors' insertion angle and its traction resistance are the main subjects of this study. Twenty trials were realized using threaded suture anchors in four diferents angulations (30º /45º /60º /90º) in human bone (distal femur) and another twenty trials in artificial bone (SawboneTM). The anchors were pulled out being tractioned uprightly from its bone surface by a Kratos Universal test machine. The human bone results found no relation between the main subjects of this study, so whithout statistical value. On the other hand at the artificial bone the insertion angle of 90º beared more traction, being statistically significant compared to the other angles.


Subject(s)
Humans , Orthopedics , Sutures , Biomechanical Phenomena , Cadaver , Tensile Strength
17.
Acta ortop. bras ; 10(2): 41-47, abr.-jun. 2002.
Article in Portuguese | LILACS | ID: lil-414371

ABSTRACT

Com o objetivo de avaliar o enfraquecimento causado pela confecção de janela óssea cortical, os autores confeccionaram uma janela circular no osso cortical da diáfise de oito fêmures de carcaças de cães e uma janela quadrada nos oito pares destes fêmures, com diagonal semelhante ao diâmetro da janela circular contralateral. As peças anatômicas foram submetidas a teste de tensão torcional em uma máquina de ensaios mecânicos; obtendo-se o torque máximo e a rigidez à torção. Os resultados mostraram que, para o fêmur com janela circular, o torque máximo médio foi de 13,65 ± 5,12 Nm, e a rigidez média foi de 1,18 ± 0,45 Nm/grau, enquanto que para a janela quadrada o torque máximo médio foi de 13, 39 ± 5,23 Nm, e a rigidez média foi de 1,05 ± 0,41 Nm/grau. A resistência nos ossos com janela circular e quadrada submetidos à tensão torcional foi praticamente igual, fato este corroborado pela análise estatística que não revelou diferença significante (p = 0,05).


Subject(s)
Animals , Dogs , Torsion Abnormality , Bone and Bones , Femur/injuries , Femur/pathology , Femur , Biomechanical Phenomena , Biopsy , Tensile Strength
18.
Rev. bras. ortop ; 35(10): 390-395, out. 2000. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-339720

ABSTRACT

Os autores submeteram montagens de 100mm de comprimento, formadas com várias combinações de módulos de 25 ou de 50mm da endoprótese modular de titânio empregada nas reconstruções de tumores ósseos, a ensaios mecânicos de compressão axial excêntrica e de torção, calculando a rigidez do sistema. Concluem que a variação dos tipos de montagens e a direção de aplicação excêntrica de força não foram fatores determinantes de variações no índice de rigidez das montagens.


Subject(s)
Prostheses and Implants , Titanium , Biomechanical Phenomena
19.
Rev. Hosp. Clin. Fac. Med. Univ. Säo Paulo ; 54(6): 181-6, Nov.-Dec. 1999. ilus, tab, graf
Article in English | LILACS | ID: lil-260494

ABSTRACT

Cylindrical specimens of bone measuring 15 mm in diameter were obtained from the lateral cortical layer of 10 pairs of femurs and tibias. A central hole 3.2 mm in diameter was drilled in each specimen. The hole was tapped, and a 4.5 mm cortical bone screw was inserted from the outer surface. The montage was submitted to push-out testing up to a complete strip of the bone threads. The cortical thickness and rupture load were measured, and the shear stress was calculated. The results were grouped according to the bone segment from which the specimen was obtained. The results showed that bone cortex screw holding power is dependent on the bone site. Additionally, the diaphyseal cortical bone tissue is both quantitatively and qualitatively more resistant to screw extraction than the metaphyseal tissue.


Subject(s)
Bone Screws , Femur/physiology , Tibia/physiology , Diaphyses/injuries , Diaphyses/surgery , Femur/injuries , Femur/surgery , Tensile Strength , Tibia/injuries , Tibia/surgery
20.
Acta ortop. bras ; 7(1): 14-20, jan.-mar. 1999. ilus, tab
Article in Portuguese | LILACS | ID: lil-248047

ABSTRACT

Foi desenvolvido um método para, com o emprego de uma máquina universal de ensaios mecânicos, verificar a precisäo dos tensionadores dinamométricos comumente utilizados na cirurgia de instalaçäo de fixadores externos para uso no método de Ilizarov. Os autores concluem que os dispositivos testados apresentam boa reprodutibilidade de resultados, mas os valores medidos säo inexatos, tanto em comparaçäo com o valor real como entre os aparelhos.


Subject(s)
Humans , Biomechanical Phenomena , External Fixators , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL